# Twelve-bay stress tests
Development reference and historical context. For current operating instructions, use the [user manual](../README.md). Acceptance applies only to the source and artifacts identified in each record.
[Documentation index](README.md) · [Cartridge configuration](cartridges.md) · [Shutdown](power.md)
M11 exercises twelve devices together and failures during media writing. The
software tests run on the build workstation. The separate physical procedure
below is for the assembled Pi; no virtual result certifies its wiring, power
budget, USB hubs, storage controllers or display.
## Run the virtual tests
Complete the [boot-image prerequisites](boot.md), then run sequentially:
```sh
make rootfs PROFILE=cli
make rootfs-test
make system-card PROFILE=cli
make media-image-test
make stress-test
```
`make stress-test` compiles two test-only static ARM workloads, boots the actual
packaged CLI image and Pi kernel, then runs the media failure suite. To repeat
only the latter after those prerequisites:
```sh
make media-fault-test
```
No host disk or physical USB device is passed through. All media are disposable
regular files inside a new `out/m11-vm.*` or `out/m11-faults.*` directory. QEMU runs
inside the existing private network namespace. The SYSTEM root is a protected
read-only virtual disk; the twelve additional USB disks stress all twelve bay
slots. Earlier boot tests cover a removable USB SYSTEM itself.
The virtual controller explicitly has twelve USB 2 and USB 3 ports. Its live
controller identity is discovered before generating the test map. This is not a
map to install on the Pi. Physical hub chains and USB 2/3 aliases must be calibrated
on the actual machine using [the cartridge guide](cartridges.md).
The test records:
- Three cold-start pairs with empty and fully populated bays, using the actual
ordinary-user console prompt and identical image/controller configuration.
- Twelve correct cartridge IDs and serials, followed by three simultaneous
removal/insertion cycles with reversed enumeration and rotated bay positions.
- Eleven direct-I/O readers checking known bytes while DATA writes and flushes
64 MiB. Per-thread intervals must overlap, and QEMU's real block counters must
show reads/writes for every disk.
- Console readiness while the cartridge daemon is deliberately held at an
event gate with all twelve disks present. No sleep releases that gate.
- Native reboot during sustained DATA writes, independent `e2fsck`, exact payload
verification, another boot with a different device declaration order, and halt.
- Kernel logs checked for unexpected I/O failures, USB resets, filesystem errors
and controller failures. Intentional fault tests have separate logs.
Boot samples, shutdown events, bay inventories, I/O counters and kernel logs stay
beside the images. A greater-than-100 ms device-load change must receive the
recorded review explanation; it must not be hidden by selecting a faster sample.
Three emulator samples do not establish a Pi performance claim.
The fault suite injects actual EIO during writing, cache flush and readback. Other
cases interrupt a confirmed transfer after at least 64 MiB by cancellation,
worker termination or daemon termination. Failed operations must remain failed
across restart, the daemon must remain usable, and none may acquire SAFE status.
A test-only QEMU bandwidth limit keeps the large transfer observable; production
code has no corresponding delay. See [QEMU fault injection](https://www.qemu.org/docs/master/devel/testing/blkdebug.html).
## Prepare the physical session
Use twelve labelled test cartridges and a written bay inventory. Include the
intended SYSTEM, a backed-up or disposable DATA cartridge, and the PROGRAM,
ENVIRONMENT and hardware cartridges you plan to use. Keep a known-working SYSTEM
available for rollback. Record the Pi revision, EEPROM version, hub/controller
models, cable arrangement, power source, storage serials and image hashes.
Label physical bays `01` through `12`. Confirm one device at a time with
`fds topology` and `fds bay N`, then create the permanent machine map following
the cartridge guide. Check both USB 2 and USB 3 modes where supported. A serial
identifies the cartridge, while the stable controller/port path identifies its
bay; the `/dev/sdX` name is not a bay label. Do not copy the VM map.
No destructive operation is necessary merely to collect diagnostics. For write
stress, use test media whose contents can be replaced. Any `fds burn` or
`fds format` operation still requires its exact per-operation confirmation.
## Capture evidence on the target
Copy [capture-hardware](../../tools/capture-hardware) to the DATA cartridge. At the
FDS console, run it explicitly through Bash; DATA intentionally does not permit
direct execution:
```sh
bash /data/capture-hardware /data/capture-before
```
The destination must be a new absolute directory. It is created private to the
current user. The script collects FDS status, topology, boot events, kernel logs,
USB/block inventories, mounts, network links and package versions. It writes a
status table and checksums. It does not change services, mounts, firmware, disks
or networking. A command denied to the ordinary user is recorded with its exit
status; use an administrative maintenance session for the missing diagnostic if
needed. A successful capture is not a hardware PASS.
Choose a new directory for every capture. If DATA itself is under investigation,
write to `/tmp/capture-before` instead and copy the directory to trusted storage
before shutdown; `/tmp` is volatile. Review captured device serials and network
identifiers before sharing the files.
## Physical acceptance sequence
Copy the [physical session template](../../tests/hardware/session-template.json)
and fill it with observed values. Null means unknown, not zero.
Record every run, including failures. The following is an initial repeatable
matrix, not evidence that it has already passed:
| Scenario | Procedure and required evidence |
| --- | --- |
| Cold boot baseline | Run five full cold boots with the intended SYSTEM and no optional media. Capture boot reports and external power-on/display timing. |
| Fully populated cold boot | Repeat five times with all twelve bays occupied. Compare prompt timing, every physical bay/serial pair and kernel errors against baseline. |
| Hot insertion | Insert each cartridge individually, then insert several together. Verify all twelve positions and expected activation. Capture before/after inventories. |
| Safe removal | Stop explicit jobs and use `fds eject N` for storage. Remove only after SAFE. Verify that reusing the same bay does not retain the old cartridge's identity or SAFE state. |
| Rotated placement | Move the test cartridges to different bays and repeat. Each bay must follow its physical position regardless of Linux disk names. |
| Simultaneous I/O | Read known files from every readable cartridge while a managed DATA job writes a known payload. Record hashes, throughput and logs; USB hardware without storage needs its own functional workload. |
| Reboot under load | Request `fds reboot`. Verify the ordered shutdown record, boot again, and compare DATA hashes. Run a filesystem check only after that filesystem is unmounted in maintenance/recovery. |
| Poweroff under load | Request `fds poweroff`; record software phases and external power/display behavior. A blocked command is not permission to unplug DATA. |
| Power and USB behavior | Observe the intended supply/battery configuration under simultaneous device load, within each component's ratings. Record undervoltage indications, resets, disconnects and any display recovery failure. |
Use external instrumentation for power applied, visible E-Ink readiness and actual
power-off. Kernel timestamps cannot measure time before the kernel starts or prove
that a flash controller honored a flush. Do not convert a VM measurement into a
physical result. Intentional power-loss or surprise-removal durability tests need
a separate disposable-data session and an explicit test plan; ordinary SAFE
acceptance does not establish power-loss durability.
## Pass, fail and follow-up
A physical run fails if a cartridge appears in the wrong bay, a confirmed write
or DATA eject reports success after an actual I/O error, a busy DATA shutdown
forces poweroff, a kernel/controller error is unexplained, or verified payloads
change. Capture logs before restarting a service or rebooting so its evidence is
not lost. Preserve both the observed failure and any later successful rerun.
Compare the same image, power source and device population when evaluating a code
change. Explain or fix a boot regression over 100 ms. Keep the idle <1 second and
normal DATA <1.5 second shutdown targets separate from measured outcomes. The
physical report should explicitly list untested devices, profiles and power modes.
No new target dependency is introduced by M11. Test workloads use Rust's standard
library; the capture script uses Bash and tools already included in the base
image. QEMU, filesystem tools and Python were existing host test dependencies.